Skip to content

Free shipping on orders $200+ · Same-day dispatch by 2 PM ET · Lot-matched COA in every box

Quality & testing

We publish the proof, not the promise.

A purity claim is a sentence; a chromatogram is evidence. Every Peptide Labs production lot passes six independent testing layers at an accredited third-party US laboratory before a single vial ships. The release results — purity, identity, endotoxin and net content — travel in the box on a lot-matched COA; sterility and elemental-impurity results are on file for every lot.

The release panel

Six layers between synthesis and shipment

Each layer answers a different question — how pure, which molecule, how clean, how much. A lot must clear all six to leave quarantine.

01

HPLC Purity — ≥99%

Each lot is run on reversed-phase HPLC (C18, water/acetonitrile gradient with 0.1% TFA) with UV detection at 214 nm, where the peptide bond absorbs. Purity is reported as main-peak area percent against total integrated area. Anything below 99.0% — or any single related-substance peak above 0.5% — fails the lot.

02

Mass-Spec Identity

Identity is confirmed by ESI-MS on the same analytical run series. The observed mass is deconvoluted from the charge-state envelope and compared against the theoretical mass of the target sequence (the same molecular weight listed on the product page). We require agreement within ±0.5 Da — close enough to catch a single-residue deletion or an oxidized methionine.

03

Endotoxin — ≤0.05 EU/mg

Bacterial endotoxin is quantified by kinetic chromogenic LAL per USP <85>, with inhibition/enhancement controls run on each matrix. Our release limit of 0.05 EU/mg sits well below typical cell-culture thresholds, so a vial won't be the variable that confounds a sensitive in-vitro assay.

04

USP <71> Sterility

Finished vials — not just bulk material — are tested by membrane filtration and incubated 14 days in both fluid thioglycollate (anaerobes) and soybean-casein digest media (aerobes and fungi). Growth promotion and method-suitability controls accompany every run. No turbidity, no release. The result is held on the lot file and available on request.

05

ICP-MS Heavy Metals

Elemental impurities are screened by inductively coupled plasma mass spectrometry following USP <232>/<233>, with lead, arsenic, cadmium and mercury quantified to parts-per-billion sensitivity. Results are reported in ppm against the lot specification; any element above its limit fails the lot. The report is held on the lot file and available on request.

06

Net-Content Assay

Label claim is verified per lot by quantitative HPLC against a certified external reference standard, corrected for peptide content rather than gross lyophilizate weight — counterions and residual water don't count. A vial labeled 10 mg must assay between 95% and 105% of claim to ship.

Chain of custody

From reactor to your bench

Six checkpoints, one unbroken record. The lot number assigned at synthesis follows the material through every gate below.

  1. Synthesis

    Solid-phase synthesis, cleavage and preparative purification are completed at our audited synthesis partner. Every lot receives a unique identifier at this point — the same lot number applied to your vial at fill.

  2. Internal QC gate

    Purified bulk is screened by HPLC and mass-spec at the synthesis partner before fill-finish. Material that doesn't clear specification never reaches a vial, let alone a third-party lab.

  3. Independent third-party analysis

    Samples from the finished, vialed lot are sent to an accredited, independent US analytical laboratory for the release panel. The lab has no stake in whether a lot passes — that's the point.

  4. Quarantined until pass

    The entire lot sits in quarantine, physically segregated from releasable inventory, until every result is back and within specification. A single out-of-spec value fails the whole lot. No partial releases, no exceptions.

  5. Lot-matched COA printed

    Passing results are compiled into a Certificate of Analysis tied to that specific lot number. It's printed and packed with every order from the lot — the certificate in your box describes the vial in your hand.

  6. Cold storage & same-day dispatch

    Released lots move to temperature-controlled storage at −20 °C. Orders confirmed before 2 PM ET ship the same business day in plain, unbranded insulated packaging; lyophilized powder is stable at ambient temperature for the 2–3 day transit. Refrigerate on receipt.

Reading the document

How to read your COA

Every Peptide Labs Certificate of Analysis is organized into the same five blocks, top to bottom. Here's what each one tells you — and what to look for.

The header ties the document to a single production run: compound name and sequence, catalog number, lot number, fill mass, manufacture date and retest date. Check the lot number here against the lot number on your vial first — if they match, everything below describes your exact vial.
The full chromatogram is reproduced, not just a summary number. The main peak is the target peptide; purity is its area percent at 214 nm. Look at the baseline around the main peak — a clean trace with no shoulder peaks or late-eluting impurities is what ≥99% actually looks like. Retention time, column, gradient and run parameters are listed so the analysis can be reproduced.
Two numbers side by side: the theoretical mass calculated from the peptide sequence, and the observed mass deconvoluted from the ESI-MS spectrum. They should agree within ±0.5 Da. This is the identity check — purity tells you how much of one thing is in the vial; mass-spec tells you that the one thing is the right thing.
The cleanliness-and-quantity block: the LAL endotoxin result in EU/mg against our ≤0.05 EU/mg limit, and the net-content assay against label claim (95–105%). Both are run on finished vials from the lot, so the result reflects the sealed product, not just the bulk powder. The USP <71> sterility and ICP-MS elemental-impurity results for the lot are kept on file and available on request.
The certificate closes with the reviewing analyst's signature, the date of review, and the independent laboratory's identity and accreditation. This block is what separates a real COA from a marketing document: a named, accredited third party stands behind every value above it.

Verify any lot

Your vial, your certificate

COA lookup

Every order ships with its paper COA — and released lots are published here.

Enter the lot number on your vial to see the independent laboratory results for that exact production lot — purity, identity, endotoxin and net content — with the full PDF linked where published. Certificates are published as lots are released; any lot not yet online can be requested from support@peptidelabs.supply.

Lot format: PL-#### · applied to every vial at fill

All Peptide Labs compounds are supplied strictly for in-vitro laboratory research by qualified professionals. They are not for human or veterinary use of any kind, and nothing on this page is a claim of therapeutic effect.